Forensic Science International Supplement Series
Volume 1, Issue 1 , Pages 29-32, December 2009

The toxicological challenges in the European research project DRUID

  • Kristof Pil

      Affiliations

    • Department of Clinical Chemistry, Microbiology and Immunology, Ghent University, De Pintelaan 185, 9000 Ghent, Belgium
  • ,
  • Elke Raes

      Affiliations

    • Department of Clinical Chemistry, Microbiology and Immunology, Ghent University, De Pintelaan 185, 9000 Ghent, Belgium
  • ,
  • Alain G. Verstraete

      Affiliations

    • Department of Clinical Chemistry, Microbiology and Immunology, Ghent University, De Pintelaan 185, 9000 Ghent, Belgium
    • Laboratory of Clinical Chemistry-Toxicology, Ghent University Hospital, De Pintelaan 185, 9000 Ghent, Belgium
    • Corresponding Author InformationCorresponding author at: Department of Clinical Chemistry, Microbiology and Immunology, Ghent University, Policlinic 8, 2nd floor, De Pintelaan 185, 9000 Ghent, Belgium. Tel.: +32 9 332 34 07; fax: +32 9 332 49 85.

Received 21 July 2009; accepted 2 August 2009.

Abstract 

Within the epidemiological studies of the integrated European research project DRUID (Driving Under the Influence of Drugs, alcohol and medicines), 13 laboratories from across Europe will analyse whole blood, oral fluid (OF) or urine from the general driving population and injured drivers. To ensure the comparability of toxicological results from the different studies, the collection of samples, analytical methods, target analytes and analytical cut-offs have been standardized for all laboratories involved.

Target analytes were selected based on suspected impairing effects and prevalence. Twenty-three drugs are included in the ‘core list’ for which analysis is mandatory: ethanol, amphetamine, MDMA, MDA, MDEA, methamphetamine, cocaine, benzoylecgonine, THC, THC-COOH, 6-acetylmorphine, diazepam, flunitrazepam, alprazolam, clonazepam, oxazepam, nordiazepam, zolpidem, zopiclone, lorazepam, morphine, codeine and methadone. Additionally, 28 other drugs will be analysed in 1–12 countries.

All whole blood samples are collected in glass Vacutainer-type tubes containing sodium fluoride and potassium oxalate. Based on a comparative study of 10 collection devices, it was decided to collect oral fluid using the Statsure™ device. Since only a small sample volume is available (5–10mL blood and 1mL oral fluid), all laboratories have to develop methods for simultaneous detection of the target analytes. All laboratories agreed to use either LC–MS–MS or GC–MS in SIM-mode. Proficiency testing for both blood and oral fluid are organized.

Analytical cut-offs were established for the core list based on those used in ROSITA-2, SAMHSA cut-off values for oral fluid and recommendations from an expert meeting in Talloires.

Because of practical and legal considerations, different sample types are used: whole blood, serum/plasma and oral fluid. Literature on correlation between analyte concentrations in these body fluids is limited, which makes several comparisons of study results difficult: (1) comparison of epidemiological (blood, oral fluid and urine) and experimental studies (serum and plasma) performed in DRUID and (2) comparisons within the epidemiological studies themselves (most countries: oral fluid in road-side survey, blood in hospital studies).

A combination of literature findings, new findings from DRUID and semi-quantitative results will likely have to be used to solve these problems.

Keywords: Driving under the influence, Epidemiology, Analytical methods, DRUID

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1875-1741(09)00013-5

doi:10.1016/j.fsisup.2009.08.001

Forensic Science International Supplement Series
Volume 1, Issue 1 , Pages 29-32, December 2009